Panasonic
CU4KE31NBU CSMKE18NKU CSMKE24NKU Panasonic BTU Heat Pump Wall Mount Dual Zone System
$4,331.00

CU4KE31NBU CSMKE18NKU-24k

Panasonic Split Systems

Outdoor Unit Specifications

TypeOutdoor Unit
UnitHeat Pumps
Performance & Electrical Ratings
Capacity Cooling (Btu/h)29,000 / 28,600
Capacity Heating (Btu/h)30,600
Air Circulation (High) Cooling CFM1,942
Number of Connectable Indoor Units2 ~ 4
SEER - Cooling17.2
EER - Cooling11.2
HSPF - Heating9.3
Power Supply V, Phase, Hz230V / 208V, 1Ph, 60Hz
Running Ampere - ACooling: 11.4 / 12.6
Heating: 10.1 / 11.2"
Power Input - WCooling: 2,600 / 2,560
Heating: 2,300
Maximum Fuse Size - Amps20A
Features
ControlsMicroprocessor
Fan SpeedsAuto (Hi, Me, Lo)
CompressorDC Inverter
Refrigerant / Amount Charged at Shipment 1b.R-410A / 6.17
Refrigerant ControlElectric Expansion Valve
Operating Sound (Hi) - dB-ACooling: 53
Heating: 55
Refrigerant Tube Connections - TypeFlare
Max. Allowable Tubing Length Ft100 (per Unit) 230 (per System with additional Refrigerant)
Refrigerant Tube Diameter - Narrow Tube - inches1/4" x 4
Refrigerant Tube Diameter - Wide Tube - inches3/8" x 2 + 1/2" x 2
Dimensions & Weight
Height (inches)35-1/32"
Width (inches)35-7/16"
Depth (inches)12-19/32"
Net Weight (lbs.)181

 

Indoor Unit Specifications:

CS-MKE18NKU

TypeWall Mounted
UnitHeat Pumps
Power Source230V-208V, 1 PH, 60 Hz
Running Ampere - A0.15 / 0.17
Power Input - W35
Capacity Cooling (Btu/h)17,500
Capacity Heating (Btu/h)20,400
Moisture Removal - High - Pints/H4.89
Dimensions & Weight
Height (inches)11"-23/32"
Width (inches)41"-15/16"
Depth (inches)8"-19/32"
Net Weight (lbs.)26.5
Air Circulation (H.M.L) Cooling CFM500 / 447 / 377
Air Circulation (H.M.L) Heating CFM500 / 447 / 377
Operating Sound (H/L) Cooling - dB-A41 / 38 / 34 / 28
Operating Sound (H/L) Heating - dB-A40 / 37 / 34 / 28
Refrigerant Tube Diameter - Narrow Tube - inches1/4"
Refrigerant Tube Diameter - Wide Tube - inches1/2"
Elevation Difference - Outdoor Above - ftMax. 50*
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.
Elevation Difference - Outdoor Below - ftMax. 50*
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.

CS-MKE24NKU

TypeWall Mounted
UnitHeat Pumps
Power Source230V-208V, 1 PH, 60 Hz
Running Ampere - A0.20 / 0.22
Power Input - W45
Capacity Cooling (Btu/h)24,200
Capacity Heating (Btu/h)29,000
Moisture Removal - High - Pints/H4.89
Dimensions & Weight
Height (inches)11"-23/32"
Width (inches)41"-15/16"
Depth (inches)8"-19/32"
Net Weight (lbs.)26.5
Air Circulation (H.M.L) Cooling CFM541 / 500 / 435
Air Circulation (H.M.L) Heating CFM541 / 500 / 435
Operating Sound (H/L) Cooling - dB-A44 / 41 / 38 / 30
Operating Sound (H/L) Heating - dB-A43 / 40 / 37 / 30
Refrigerant Tube Diameter - Narrow Tube - inches1/4"
Refrigerant Tube Diameter - Wide Tube - inches5/8"
Elevation Difference - Outdoor Above - ftMax. 50*
* This is maximum elevation difference when the indoor unit is located above the outdoor unit."
Elevation Difference - Outdoor Below - ftMax. 50*
* This is maximum elevation difference when the indoor unit is located above the outdoor unit."

Download Our Manuals

Currently no manuals available for this product. Please check product description or call our sales support team if you have any further queries.

Currently no specifications available for this product. Please check product description or call our sales support team if you have any further queries.

Heating And Cooling Companies - Heat Pumps & Air Conditioners

Get Service Calls